| 1 | Project SCCI RH / Integrated modular SCCI electrical system | Complete system | KiCad source |
| 2 | Project SCCI RH S4 / Shared reference and interfaces | Monitoring cell | KiCad source |
| 3 | Project SCCI RH S4 / Source 0: current and phase charge | Monitoring cell | KiCad source |
| 4 | Project SCCI RH S4 / Source 1: current and phase charge | Monitoring cell | KiCad source |
| 5 | Project SCCI RH / monitoring-cell integration taps | Monitoring cell | KiCad source |
| 6 | Project SCCI RH S4 / Dual setpoint and external contracts | Current driver | KiCad source |
| 7 | Project SCCI RH S4 / Source 0: regulated sink and polarity bridge | Current driver | KiCad source |
| 8 | Project SCCI RH S4 / Source 0: independent duration and sticky admission | Current driver | KiCad source |
| 9 | Project SCCI RH S4 / Source 1: regulated sink and polarity bridge | Current driver | KiCad source |
| 10 | Project SCCI RH S4 / Source 1: independent duration and sticky admission | Current driver | KiCad source |
| 11 | Project SCCI RH S4 / Isolated SPI, control and supplied power | Recording front end | KiCad source |
| 12 | Project SCCI RH S4 / RHD2216 / sixteen sampled differential streams | Recording front end | KiCad source |
| 13 | Project SCCI RH S4 / Inputs 00-03 / protected recording | Recording front end | KiCad source |
| 14 | Project SCCI RH S4 / Inputs 04-07 / protected recording | Recording front end | KiCad source |
| 15 | Project SCCI RH S4 / Inputs 08-11 / protected recording | Recording front end | KiCad source |
| 16 | Project SCCI RH S4 / Inputs 12-15 / protected recording | Recording front end | KiCad source |
| 17 | Project SCCI RH S4 / Shared reference / passive body bias | Recording front end | KiCad source |
| 18 | Project SCCI RH / recording-front-end integration taps | Recording front end | KiCad source |
| 19 | Project SCCI RH S4 / Route interfaces and monitored returns | Contact router | KiCad source |
| 20 | Project SCCI RH S4 / Source 0 / sixteen-contact output | Contact router | KiCad source |
| 21 | Project SCCI RH S4 / Source 1 / sixteen-contact output | Contact router | KiCad source |
| 22 | Project SCCI RH S4 / Candidate preload and active addresses | Contact router | KiCad source |
| 23 | Project SCCI RH S4 / Commit, acknowledgement and rearm | Contact router | KiCad source |
| 24 | Project SCCI RH S4 / Conflict and bank enables | Contact router | KiCad source |
| 25 | Project SCCI RH S4 / Interfaces and handoff | Independent supervision | KiCad source |
| 26 | Project SCCI RH S4 / 18 body-side terminal guards | Independent supervision | KiCad source |
| 27 | Project SCCI RH S4 / Host supply windows | Independent supervision | KiCad source |
| 28 | Project SCCI RH S4 / Host supply windows / 2 | Independent supervision | KiCad source |
| 29 | Project SCCI RH S4 / AFE supply windows | Independent supervision | KiCad source |
| 30 | Project SCCI RH S4 / AFE supply windows / 2 | Independent supervision | KiCad source |
| 31 | Project SCCI RH S4 / Heartbeat and startup | Independent supervision | KiCad source |
| 32 | Project SCCI RH S4 / Current quiet window | Independent supervision | KiCad source |
| 33 | Project SCCI RH S4 / Differential compliance | Independent supervision | KiCad source |
| 34 | Project SCCI RH S4 / Secondary phase duration | Independent supervision | KiCad source |
| 35 | Project SCCI RH S4 / Sticky permission and rearm | Independent supervision | KiCad source |
| 36 | Project SCCI RH S4 / Sticky permission and rearm / 2 | Independent supervision | KiCad source |
| 37 | Project SCCI RH S4 / Source 0 phase permission | Independent supervision | KiCad source |
| 38 | Project SCCI RH S4 / Source 1 phase permission | Independent supervision | KiCad source |
| 39 | Project SCCI RH S4 / RHD input windows 0 | Independent supervision | KiCad source |
| 40 | Project SCCI RH S4 / RHD input windows 1 | Independent supervision | KiCad source |
| 41 | Project SCCI RH S4 / RHD input windows 2 | Independent supervision | KiCad source |
| 42 | Project SCCI RH S4 / RHD input windows 3 | Independent supervision | KiCad source |
| 43 | Project SCCI RH S4 / RHD input windows 4 | Independent supervision | KiCad source |
| 44 | Project SCCI RH S4 / AFE blank and isolated status | Independent supervision | KiCad source |
| 45 | Project SCCI RH S4 / AFE blank and isolated status / 2 | Independent supervision | KiCad source |
| 46 | Project SCCI RH S4 / External defaults | Independent supervision | KiCad source |
| 47 | Project SCCI RH / supervision integration taps | Independent supervision | KiCad source |
| 48 | Project SCCI RH S4 / Interfaces and rail handoff | Power | KiCad source |
| 49 | Project SCCI RH S4 / Protected pack and input disconnect | Power | KiCad source |
| 50 | Project SCCI RH S4 / Always-on supervisor 3.3 V | Power | KiCad source |
| 51 | Project SCCI RH S4 / Always-on supervisor 5 V | Power | KiCad source |
| 52 | Project SCCI RH S4 / Host logic 3.3 V | Power | KiCad source |
| 53 | Project SCCI RH S4 / Host and module input 5 V | Power | KiCad source |
| 54 | Project SCCI RH S4 / Native battery and startup qualification | Power | KiCad source |
| 55 | Project SCCI RH S4 / Native battery and startup qualification / 2 | Power | KiCad source |
| 56 | Project SCCI RH S4 / Native battery and startup qualification / 3 | Power | KiCad source |
| 57 | Project SCCI RH S4 / Host 15 V boost | Power | KiCad source |
| 58 | Project SCCI RH S4 / Stimulation 24 V boost | Power | KiCad source |
| 59 | Project SCCI RH S4 / Floating recording power module | Power | KiCad source |
| 60 | Project SCCI RH S4 / Floating AFE 3.45 V regulator | Power | KiCad source |
| 61 | Project SCCI RH S4 / Floating AFE +5.30 V regulator | Power | KiCad source |
| 62 | Project SCCI RH S4 / Floating AFE -5.10 V regulator | Power | KiCad source |
| 63 | Project SCCI RH S4 / Existing package and host endpoints | Monitoring and companion transport | KiCad source |
| 64 | Project SCCI RH S4 / Existing package and host endpoints / 2 | Monitoring and companion transport | KiCad source |
| 65 | Project SCCI RH S4 / Dedicated eight-channel raw conversion | Monitoring and companion transport | KiCad source |
| 66 | Project SCCI RH S4 / Independent ADC reference and bypass | Monitoring and companion transport | KiCad source |
| 67 | Project SCCI RH S4 / Raw current and scaled voltage filtering | Monitoring and companion transport | KiCad source |
| 68 | Project SCCI RH S4 / Divided power observations | Monitoring and companion transport | KiCad source |
| 69 | Project SCCI RH S4 / Isolated wired processed-feature companion | Monitoring and companion transport | KiCad source |
| 70 | Project SCCI RH S4 / Charge ADC and health host handoff | Monitoring and companion transport | KiCad source |
| 71 | Project SCCI RH S4 / Controller carrier / interface index | Controller carrier | KiCad source |
| 72 | Project SCCI RH S4 / BT40F / actual nRF5340 physical pads | Controller carrier | KiCad source |
| 73 | Project SCCI RH S4 / Module normal-voltage supply and SWD | Controller carrier | KiCad source |
| 74 | Project SCCI RH S4 / Four physical 165 devices / parallel observations | Controller carrier | KiCad source |
| 75 | Project SCCI RH S4 / Matched peripheral handoff connectors | Controller carrier | KiCad source |
| 76 | Project SCCI RH S4 / Matched peripheral handoff connectors / 2 | Controller carrier | KiCad source |
| 77 | Project SCCI RH S4 / Matched peripheral handoff connectors / 3 | Controller carrier | KiCad source |
| 78 | Project SCCI RH S4 / Passive reset defaults / explicit recovery | Controller carrier | KiCad source |
| 79 | Project SCCI RH S4 / Passive reset defaults / explicit recovery / 2 | Controller carrier | KiCad source |
| 80 | Project SCCI RH S4 / Passive reset defaults / explicit recovery / 3 | Controller carrier | KiCad source |